Measurement of radon gas concentration in cement samples by using | ||
Kirkuk Journal of Science | ||
Article 1, Volume 8, Issue 3, September 2013, Pages 48-54 PDF (0 K) | ||
DOI: 10.32894/kujss.2013.83420 | ||
Author | ||
Hassan. M. Jaber AL-Taii | ||
Abstract | ||
In this work, we have measured the concentration of radon gas in eight cement samples from different origins by using long-term measurement of radon decay products with solid state track detectors which alpha particles that emitted from radon gas was detected using (LR115II) nuclear track detector. The obtained results show that, the highest average radon gas concentration in cement samples was found in Iraq cement (Samawa) sample, which was (10.625 Bq/m 3 ) ,while the lowest one was found in (Saudi) sample, and found to be (2.486Bq/m 3 ). The present results show that the radon gas concentration in all cement samples is not below the allowed limit from (ICRP) agency. | ||
Keywords | ||
Radon gas; II detector; Cement Samaea; Density track; activity | ||
Statistics Article View: 189 PDF Download: 128 |