Abstract | ||
Aim of the study: is to assess the tissue compatibility of implanted dental material. Material and methods: fourteen albino rabbits were used for subcutaneous implant for 14 days of different dental metallic material includes titanium, cobalt chrome and nickel chrome. Result: titanium and cobalt chrome show fibrous capsule formation while nickel chrome shows necrotic tissue filled the area of the implant. Conclusion: to minimize biologic risk, dentists should select dental materials that have the low tissue toxicity, allergy and sensitivity, with proper manufacturing and quality control of metals. | ||