Testing the Applicability of Submerged Hollow Fiber Membrane Bioreactor (MBR) Technology for Municipal Wastewater Treatment in Iraq | ||
Engineering and Technology Journal | ||
Article 1, Volume 30, Issue 19, November 2012, Pages 3467-3473 PDF (170.76 K) | ||
DOI: 10.30684/etj.30.19.14 | ||
Authors | ||
Talib R. Abbas; Mohammed A. Abdul-Majeed; Inmar N.Ghazi | ||
Abstract | ||
Operation of a one module hollow fiber submerged type MBR system was tested in this work. The system was operated at fixed permeate flowrate of 12 l/hr. The hydraulic retention time of the aeration tank was about 8.3 hr. The mixed liquor suspended solid (MLSS) concentration was maintained in the range 5000- 5500 mg/l. The results show the workability of this system under Iraqi conditions without any difficulties. About 85% chemical oxygen demand (COD) removal was achieved. The value of turbidity is well below 0.61 NTU throughout the operation time. | ||
Keywords | ||
MBR; wastewater; Activated Sludge; Hollow fiber membrane | ||
Statistics Article View: 183 PDF Download: 70 |