Reducing the Concentrations of Chromium and Cyanide from Industrial Wastewater By Chemical Treatments Substitutes | ||
Engineering and Technology Journal | ||
Article 1, Volume 29, Issue 6, April 2011, Pages 271-276 PDF (240.32 K) | ||
DOI: 10.30684/ etj.29.6.16 | ||
Abstract | ||
The attempt on Chromium and Cyanide removing from industrial wastewater of chemical plotting was achieved by using the natural polymer ( animal gelatin 0 and calcium salts . Among three treatments with non treated wastewater , we were selected the treatment with calcium chloride and gelatin in which the chromium (Cr +6 ) reduced from 3.5 mg /l to 0.86 mg / l and the cyanide from 0.06 mg /l to 0.03 mg / l . The treatment with gelatin alone reduced concentration of the cyanide to 0.015 mg / l. Chromium adsorption in three treatments after two hours of stabling was ranged between 37 – 75 % and cyanide 30 – 75 % which became within the limitation. | ||
Keywords | ||
Chromium and Cyanide removing; Gelatin; Industrial wastewater | ||
Statistics Article View: 191 PDF Download: 102 |