Radon Gas Concentration Measurement in Air of Al - Haswaa City in Province of Baghdad | ||
Iraqi Journal of Science | ||
Article 1, Volume 58, Issue 2, May 2018, Pages 663-668 | ||
Authors | ||
Basim Khalaf Rejah; Gofraan Thaar Ashoor | ||
Abstract | ||
In this study the radon gas concentration in air in Al - Haswaa city in province of Baghdad in Iraq have been calculated using CR-39 solid–state nuclear track detector technique. A total of 8 samples selected from 8 region in Al – Haswaa city in province of Baghdad have been placed in the dosimeters for 30 day. The average radon gas concentration was found to be 486.26 Bq/m3 which is lower than the standard international limit (1100 Bq/m3). The potential alpha energy concentration and annual effective dose have been calculated. A proportional relationship between the annual effective dose and radon gas concentration within the studied region has been certified. | ||
Keywords | ||
Radon gas; detector; Air; annual effective dose; Dosimeter; Can technique | ||
Statistics Article View: 178 PDF Download: 86 |