Identification and Control of Impressed Current Cathodic Protection System | ||
Iraqi Journal for Electrical And Electronic Engineering | ||
Article 1, Volume 12, Issue 2, December 2016, Pages 214-220 PDF (0 K) | ||
DOI: 10.33762/eeej.2016.118380 | ||
Authors | ||
Bassim N. Abdul Sada; Ramzy S. Ali; Khearia A. Mohammed Ali | ||
Abstract | ||
In this paper the identification and control for the impressed current cathodic protection (ICCP) system are present. Firstly, an identification model using an Adaptive Neuro-Fuzzy Inference Systems (ANFIS) was implemented. The identification model consists of four inputs which are the aeration flow rates, the temperature, conductivity, and protection current, and one output that represented by the structure-to-electrolyte potential. The used data taken from an experimental CP system model, type impressed current submerged sample pipe carbon steel. Secondly, two control techniques are used. The first control technique use a conventional Proportional-Integral-Derivative (PID) controller, while the second is the fuzzy controller. The PID controller can be applied to control ICCP system and quite easy to implement. But, it required very fine tuning of its parameters based on the desired value. Furthermore, it needed time response more than fuzzy controller to track reference voltage. So the fuzzy controller has a faster and better response. | ||
Keywords | ||
ANFIS; Cathodic Protection; Fuzzy Controller; ICCP system; Reference electrode | ||
Statistics Article View: 131 PDF Download: 67 |