1.

Comparison of some physical properties of acrylic denture base material cured by water bath and microwave techniques

Volume 3, Issue 2, September 2003, Pages 143-147
Radhwan H Hasan

2.

Effect of Incorporation of Calcium And Fluoride Salts on Transverse Strength of Acrylic Resin

Volume 15, Issue 1, June 2015, Pages 362-368
Hind A Al-abdali; Munther N Kazanji; Gadah A Taqa

3.

Effect of Incorporation of Silver Nitrate on Transverse Strength and Impact Strength of Autopolymerizing Acrylic Resin

Volume 7, Issue 2, December 2014, Pages 1992-1999
Intisar Kadhum Farhood

4.

Effect of metal oxides on some mechanical properties of clear acrylic specific for artificial eye

Volume 13, Issue 1, December 2016, Pages 77-84
Dr. Firas Abd Kati Al-Shammari

5.

Effect of Microwave Disinfection on Transverse Strength and Hardness of Acrylic Resin Denture Base Materials

Volume 11, Issue 2, June 2011, Pages 284-291
Alaa Al-Saraj; Munther N Kazanji; Ghada Y Abdul-Rahman

6.

Effect of Siwak on Certain Mechanical Properties of Acrylic Resin

Volume 1, Issue 1, June 2014, Pages 39-49
Hanan Abdul- Rahman Khalaf

7.

Effect of the addition of bio-polymer lignin on the Transverse and Impact strength of the autopolymerizing acrylic resin.

Volume 52, Issue 3, September 2010, Pages 359-363
Basima M.A. Hussein; Thikra I. Hamad; Intisar J. Ismail

8.

Effect of Thickness and Recycling on Trans-verse Strength of Relined Acrylic Resin Denture Base.

Volume 11, Issue 1, January 2011, Pages 1-5
Nadira A Hatim; Aliaa W AL-Omari

9.

Evaluation of the Effect of silanized Zirconium Oxide nano-fillers and Plasma Treated polypropylene fibers Addition on some Properties of Heat Cured Acrylic Resin Denture Base Material

Volume 13, Issue 1, December 2016, Pages 70-76
B.D.S; Dr. Noor Falah Abdul-Hadi; M.Sc

10.

Push-out bond strength and apical microleakage of (MTA Plus, Biodentine, and Bioceramic) as apical third filling (An in vitro study)

Volume 13, Issue 1, December 2016, Pages 1-10
Dr. Abeer A. Abass B.D.S; M.Sc; Prof. Dr. Jamal A. Mehdi B.D.S

11.

Reinforced Microwave - Cured Acrylic Resin Denture Base Material with Glass Fibers

Volume 10, Issue 2, September 2010, Pages 314-321
Radhwan H. Hasan; Mohammed A Abdulla

12.

Residual Monomer and Transverse Strength Evaluation of Auto Polymerized Acrylic Resin with Different Polymerization Treatment.

Volume 7, Issue 3, December 2007, Pages 30-34
Mohammed M Sadoon; Nada Z Mohammed; Aliaa AL–Omary

13.

The effect of adding single walled carbon nanotube with different concentrations on mechanical properties of heat cure acrylic denture base material

Volume 27, Issue 3, September 2015, Pages 28-32
Rafah Adil Ibrahim

14.

The effect of the addition of silanated poly propylene fiber to polymethylmethacrylate denture base material on some of its mechanical properties

Volume 27, Issue 1, March 2015, Pages 40-47
Intisar J. Ismaeel; Hasanain K.A. Alalwan; Mustafa M.J

15.

The study aims to evaluate the effect of some commercially available natural products (soda+ vinegar, soda +thymol , saturated salt solution) in relation to the commercial denture cleansers (Protifex) ,on surface roughness and hardness dimensional accuracy of acrylic denture base materials. one hundred samples were prepared from heat activated acrylic resin denture base material, they are (1cm*1cm*2mm length, width and thickness respectively). After that, half of the samples for each group were immersed for ½ hr per day in the denture cleanser, the other half of the samples immersed for 8 hr per day in the denture cleanser through one month. The denture cleansers used are three solutions prepared freshly everyday for immersion of the samples. The surface roughness of the samples were tested by using Stylus profilometer(Talysurf 10, England), while the hardness of the samples were tested by using Rockwell hardness tester (Wolpert, Germany), the mean is taken for each group and evaluated by using one way analysis of variance test, Dunnet T-test to compare the groups. The results demonstrated that there were no significant differences in the surface roughness and hardness, but with significant difference between treats of length of acrylic resin denture base material and duration of immersion at (P=0.05). All the prepared natural solutions would be accepted in relation to effect on surface roughness , dimensional accuracy, and hardness of acrylic denture base material.

Volume 2, Issue 2, December 2013, Pages 137-144
Suad G. Al Nakash

16.

Visible Light Cure Fiber Frame Work Reinforcement of Acrylic Resin Denture Base Material. A Comparative Study.

Volume 14, Issue 2, December 2014, Pages 173-181
Aliaa W AL-Omari



Journal Management System. Powered by ejournalplus.com